Covers the main duties for landlords, letting agents, commercial occupiers and property managers: CP12 gas safety certificates, the Renters’ Rights Act 2025, EICR, EPC and MEES, F-Gas Regulation and TM44 air conditioning inspections. General guidance from CP12 Gas Heating and Cooling — a Gas Safe registered engineering business — not legal advice.
Gas Safe 638057 · F-Gas certified · 20+ engineers · 24/7 emergency · DBS checked
WHAT OUR COMPLIANCE HUB COVERS
The compliance duties below apply across residential lettings and commercial premises. Each section is a plain-English overview of what the duty is, who it applies to, and where to get authoritative guidance. Nothing here is legal advice — for a specific position, check with a solicitor and refer to gov.uk and the Gas Safe Register.
Annual gas safety check required for every rented property. Record issued within 28 days. Held for two years.
In force from 1 May 2026. Ties possession claims to statutory compliance. A lapsed CP12 blocks eviction.
Electrical Installation Condition Report required every five years. Remedial work must be closed within 28 days.
EPC band E now. Band C by 1 October 2030 for privately rented homes. Boiler condition is a direct driver.
Refrigerant work restricted to F-Gas certified engineers and businesses. Leak checks scheduled to plant charge.
Air conditioning over 12kW combined capacity requires a TM44 inspection every five years, lodged on the register.
CP12 GAS SAFETY RECORDS
Under the Gas Safety (Installation and Use) Regulations 1998, a landlord must arrange an annual gas safety check by a Gas Safe registered engineer on every gas appliance and flue at the property. The record of that check is the CP12 — properly called a Gas Safety Record. It must be issued to existing tenants within 28 days of the check, and to new tenants before they move in. Landlords must keep records for at least two years.
The annual check can be carried out up to two months before the expiry date without losing the original anniversary. That gives a workable window for scheduling and avoids gaps in cover. Records issued by CP12 Gas Heating and Cooling include appliance details, engineer registration number, defects noted and remedial actions required. Certificates are typically issued on the day of inspection where the property passes without remedial work.
RENTERS' RIGHTS ACT 2025
The Renters’ Rights Act 2025 came into force on 1 May 2026. It abolishes Section 21 no-fault evictions and replaces them with a Section 8 grounds process. A Section 8 notice can be struck out by the court if the landlord has not met their statutory obligations, including holding a current gas safety record. In practice this means a non-paying tenant in a property with a lapsed CP12 is effectively irremovable until compliance is restored.
Other changes under the Act include the conversion of assured shorthold tenancies to periodic tenancies, a Private Rented Sector Database expected in late 2026, a new PRS Landlord Ombudsman, and the extension of the Decent Homes Standard and Awaab’s Law to the private rented sector. The Database is expected to require safety certificates to be evidenced. Landlords and agents should verify their current position through gov.uk and their own legal adviser.
EICR — ELECTRICAL SAFETY
The Electrical Installation Condition Report is the electrical equivalent of a CP12 for rented residential property. Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, a satisfactory EICR must be in place at least every five years. A copy must be issued to the tenant within 28 days of the report, and any C1 or C2 remedial work must be completed within 28 days.
EICR is a separate duty from gas safety but often runs in the same portfolio compliance cycle. Where a property is being brought into compliance ahead of a letting or a tenant change, gas safety and electrical safety are typically scheduled together to minimise access disruption. Landlords should confirm their EICR position through a qualified electrical contractor and hold the current report alongside their CP12 certification.
EPC AND MEES
An Energy Performance Certificate rates a property’s energy efficiency from A to G. Under the Minimum Energy Efficiency Standard, a privately rented property must currently reach EPC band E to be lawfully let. The January 2026 Warm Homes Plan confirmed a new target: all privately rented homes in England and Wales must reach EPC band C by 1 October 2030, subject to a £10,000 cost cap and specific exemptions. Relevant upgrade spend from 1 October 2025 counts toward the cap.
Boiler efficiency and heating system condition are direct drivers of the EPC band. An A-rated condensing combi with time and temperature control and boiler interlock typically moves the property up the scale. Commercial premises face parallel MEES duties, with EPC band B required for large non-domestic buildings by 2031 per a June 2026 government update. Where the boiler is a limiting factor, planned replacement can be the most cost-effective route to compliance.
F-GAS REGULATION
The F-Gas Regulation controls the use of fluorinated greenhouse gases in air conditioning, refrigeration and heat pump equipment. Only F-Gas certified engineers and F-Gas certified businesses may install, service or decommission equipment containing these refrigerants, or handle the refrigerant itself. Using an uncertified installer is unlawful, invalidates most manufacturer warranties and creates liability for the site owner or the business operator.
A business with technical control of AC or refrigeration equipment is the “operator” and carries the legal duties, even where maintenance is outsourced. Duties include using certified contractors, scheduled leak checks based on the system’s CO₂-equivalent charge, prompt leak repair, record-keeping and equipment labelling. CP12 Gas Heating and Cooling holds F-Gas certification at company level, with individual engineers holding personal certifications for the refrigerant work they carry out.
TM44 INSPECTIONS
Under the Energy Performance of Buildings (England and Wales) Regulations 2012, any building whose air conditioning has a combined effective rated cooling output above 12kW must have a TM44 inspection by an accredited air conditioning energy assessor at least every five years. The report must be lodged on the national register and produced within seven days of any request. The 12kW threshold is combined across all AC units at the building — several small units routinely cross it.
Responsibility sits with whoever controls the system — owner, landlord, managing agent or tenant — depending on the lease. Non-production of a valid TM44 report can trigger Trading Standards penalties and can delay building sales, lettings and refinancing. TM44 is a separate discipline from F-Gas servicing and requires an accredited assessor. We can advise on the interaction between TM44 requirements, F-Gas servicing and PPM scheduling.
FREQUENTLY ASKED QUESTIONS
A CP12 — properly a Gas Safety Record — is the document issued after an annual gas safety check on a property. It records every gas appliance and flue checked by a Gas Safe registered engineer, any defects noted, and any remedial work required. Landlords must issue it to existing tenants within 28 days of the check and to new tenants before they move in, and hold records for at least two years.
Any building whose air conditioning has a combined effective rated cooling output above 12kW needs a TM44 inspection at least every five years. The 12kW threshold is combined across all AC units at the building — several small units routinely cross the threshold. Responsibility depends on the lease and typically sits with the owner, landlord, managing agent or tenant.
F-Gas certification covers the installation, servicing, decommissioning and refrigerant handling for equipment containing fluorinated greenhouse gases — including most air conditioning, commercial refrigeration and heat pump plant. Only F-Gas certified engineers and F-Gas certified businesses are permitted to carry out this work. Using an uncertified installer is unlawful and creates liability for the site owner or business operator.
Yes. CP12 Gas Heating and Cooling is Gas Safe registered. Our registration number is 638057. Gas Safe registration can be verified independently through the Gas Safe Register at gassaferegister.co.uk.
No. This page is a plain-English reference on the main compliance duties that apply to landlords, agents and commercial occupiers. It is general guidance from a Gas Safe registered engineering business, not legal advice. For legal advice on a specific situation, speak to a qualified solicitor. For authoritative statutory guidance, refer to gov.uk and the Gas Safe Register.